If the sample column is not forming properly between the upper and lower measurement pedestals then you may need to add more sample e. Tips and additional information Sample size is not critical to measurements, however, it is essential that the liquid column is formed between the upper and lower measurement pedestals. The files can be opened by the integrated Data Viewer software program or spreadsheet programs such as MS Excel. Spectrophotometer for full-spectrum UV-Vis absorbance analysis nm Quantifies nucleic acids, proteins and fluorescent dyes Large dynamic range: The Molecular Biology Officer can give you a log on once she is satisfied you have had training and know how to use the machine.

Uploader: Neshura
Date Added: 15 July 2009
File Size: 48.9 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 13775
Price: Free* [*Free Regsitration Required]

If the sample column is not forming properly between the upper and lower measurement pedestals then you may need to add more sample e.

Alternatively, nanidrop the surfaces by rubbing each with a dry laboratory wipe times in order to “re-condition” the surfaces. Often the problem is incomplete resuspension of your sample. The NanoDrop is set up so that you need to have a log on to use it.

  COMPAQ 6300CA NETWORK CARD DRIVER

Tips and additional information Sample size is not critical to measurements, however, it is essential that the liquid column is formed between the upper and lower measurement pedestals. Never lift the sample arm by the black fibre optic cable!

Nanodrop Spectrophotometer

Only touch the sample arm itself. It is preferable that you transfer the data to your own server for archiving and printing. Nanodrop user manual Use of the system in the Molecular Biology Facility There are Nanodrop spectrophotometers in both Anderson Stuart and Blackburn facilities Anderson Stuart online booking and Blackburn online booking calendar.

All the same, please clean the surfaces with de-ionised water after your last n. The files can be opened by the integrated Data Viewer software program or spreadsheet programs such as MS Excel. If you are not getting acceptable duplicate readings, check your sample homogeneity. Alternatively, take the data away on a USB memory stick, or just record the data in you lab book. You should not need to book more than half hour time slots for the NanoDrop.

Wiping the sample from the upper and lower pedestals with a soft laboratory wipe following each measurement dn sufficient to prevent sample carryover and avoid residue buildup. The Molecular Biology Officer can give you a log on once she is satisfied you have had training and know how to use the machine.

  DVB T 25452 DRIVER

Hence, do not give your log on information to someone else. This means that the use of the machine can be monitored and, if something goes wrong with the machine, the last user can be identified.

If you are the last user for the nanldrop, please shut down the computer after use. Executive Officer, Sydney Medical School. Data is automatically stored in your user folder.

NanoDrop ND-1000 Spectrophotometer

Please make sure you book the right one. Spectrophotometer for full-spectrum UV-Vis absorbance analysis nm Quantifies nucleic acids, proteins and fluorescent dyes Large dynamic range: Plan ahead, book time slots and stick to them. If your sample is precious, it is possible to recover it from the upper and nanorrop measurement pedestals by extraction with a pipette.